Lab Rotorless Rheometer

Product Details
Customization: Available
Max Diameter of Workpiece: 3200mm
Type: Testing Machine
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (28)
Find Similar Products

Basic Info.

Model NO.
MR-C3
Maxcapacity
>1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
<50 Tons
Power Source
AC380V
Oil Cylinder Position
Under
Type of General Rubber Machinery
Rheometer
Type of Tire Machinery
Rheometer
Power
<10kw
Voltage
220V
Using Life
<15 Years
Transport Package
Wooden Box
Trademark
CGY
Origin
China
HS Code
8477800000
Production Capacity
2600 PCS/Year

Product Description

MR-C3 Rotorless Rheometer
The curves and characteristic parameters on vulcanization of rubber materials can be obtained using rotorless Rheometer based on the measurement of the torque exerted by the rubber material on the oscillating die.
The MR-C3 Rotorless Rheometer has excellent property of reappears and stability. In a test with good mixed rubber and the timerange is 12min, the T90 may be several second difference in 4 continual experiments.
Specification
· Range of temperature control: From room temperature to 200º C
· Temperature fluctuation in die: ≤ ± 0.1º C;
· Temperature display resolution: 0.1º C;
· Rate of temperature increase: 16º C/min-25º C/min
· Measurement range of torque: 0-20Nm
· Torque resolution: 0.001Nm;
· Angle of die oscillation: ± 0.5° , ± 1° ;
· Frequency of die oscillation: 1.67Hz (100r/min)
MR-C3 Test Results
· ML Min. Torque (dNm)- The testing value of sample's curing characteristics (viscosity) before curing.
· MH Max. Torque (dNm)- The testing value of sample's shearing modulus or rigidity. Including even torque, max. Torque for returning curve, and the max. Torque during the specific period of time where no even or returning curve happens.
· Ts1 (min)- When oscillates at the angle of 0.5° Or 1° , the relative time when the torque increases to ML +1dNm. This figure shows the scorch time.
· Ts2 (min)- When oscillates at the angle of 3° Or 5° , the relative time when the torque increases to ML +2dNm. This figure shows the scorch time
· T10 (min)- The time when the torque increases to ML + 10 (MH - ML ) / 100dNm. This figure shows the scorch time.
· T30 (min)- The time when the torque increases to ML + 30 (MH - ML ) / 100dNm.
· T60 (min)- The time when the torque increases to ML + 60 (MH - ML ) / 100dNm.
· T90 (min)- The time when the torque increases to ML +90 (MH - ML ) / 100dNm. This figure shows the optimum cure time.
· Ti (min)- The time when the torque increases to ML + i (MH - ML ) / 100dNm.
· Vc- Curing speed index. Vc =100/(T90 Tsi)
Lab Rotorless Rheometer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier